Talk to a consultant+91 63869 49114
  1. Home
  2. Services
  3. Environmental Clearances, Consents & Approvals
Practice area A

Environmental Clearance, CTE/CTO and Groundwater NOC consultants

From Lucknow, we take projects across Uttar Pradesh, NCR and India from the first Terms of Reference to the last six-monthly compliance report: every environmental permission a unit or building needs.

A.1 Clearances and consents

Prior Environmental Clearance · Post-EC compliance · Consent to Establish and Consent to Operate from the SPCB · Show-cause, closure and consent-revocation proceedings · …

Prior Environmental Clearance

Environmental Impact Assessment and Environment Management Plan (EIA/EMP) studies and end-to-end EC support for industrial, mining, infrastructure and building and construction projects.

Appraised by the EAC or, in Uttar Pradesh, by State Environment Impact Assessment Authority and State Expert Appraisal Committee (SEIAA/SEAC).

For industrial, mining and infrastructure categories:

  • ToR and scoping
  • draft EIA and executive summary (Hindi and English) for the public hearing conducted by the State Pollution Control Board (SPCB)
  • the proponent's presentation and written response to issues raised
  • EAC/SEAC appraisal presentations and EDS responses

For building and construction projects and townships:

  • Form 1
  • Form 1A
  • conceptual plan and Environment Management Plan
  • appraised by SEIAA/SEAC without scoping or public hearing

All studies through NABET-accredited associates.

Post-EC compliance

Six-monthly compliance reports, amendment, transfer, splitting, validity extension and surrender.

Consent to Establish and Consent to Operate from the SPCB

Fresh grants, renewals, amendment, transfer, surrender and condition-compliance reports.

  • In Uttar Pradesh, filed through Nivesh Mitra into the Uttar Pradesh Pollution Control Board (UPPCB) Online Consent Management and Monitoring System (OCMMS)
  • through the respective state portal elsewhere

Show-cause, closure and consent-revocation proceedings

Technical reply, personal-hearing representation and a time-bound corrective action plan.

After the works are done, verification monitoring and the compliance report on which the Board considers revocation of the closure direction, followed by de-sealing, utility reconnection and bank-guarantee release under the Board's orders.

Environmental compensation levy

Computation review, mitigation planning and representation.

Services marked as delivered through associates or partners: EnvironIQ coordinates and remains your single point of contact; the partner holds the accreditation or licence.

A.2 Water, forest and land

Groundwater NOC · Surface-water abstraction · Forest clearance

Groundwater NOC

UP Ground Water Department (UPGWD) under the UP Ground Water (Management and Regulation) Act 2019, and Central Ground Water Authority (CGWA), on the NOCAP portal, for other states:

  • hydrogeologist-prepared impact assessment
  • compliance reports and the telemetry package (flow meters, piezometers with DWLR, calibration, records)

Surface-water abstraction

Permission and bulk-water agreements with the UP Irrigation & Water Resources Department.

Forest clearance

  • Stage-I/II on PARIVESH, CA land, NPV, FRA certification
  • tree-felling and transplantation permission with compensatory plantation
  • NBWL, Eco-Sensitive Zone and CRZ clearances with specialist survey partners

A.3 Monitoring and ongoing compliance

Environmental Statement (Form V) · OCEMS, CEMS and CAAQMS · DG set compliance · Environmental Compliance Status Report · …

Environmental Statement (Form V)

Preparation and filing, together with environmental performance audits.

OCEMS, CEMS and CAAQMS

Online continuous emission monitoring systems (OCEMS), continuous emission monitoring systems (CEMS) and continuous ambient air quality monitoring stations (CAAQMS): selection, installation guidance, SPCB/Central Pollution Control Board (CPCB) server connectivity, calibration coordination and data quality assurance.

DG set compliance

Diesel generator (DG) sets:

  • CPCB stack and acoustic norms
  • RECD retrofit and dual-fuel or gas conversion per Commission for Air Quality Management (CAQM) directions in NCR districts

Environmental Compliance Status Report

A dated, condition-wise report on an operating unit's consents, authorisations and EC conditions, with copies and validity dates, for lenders, buyers and boards.

Green belt and plantation

Green-belt development and Miyawaki plantation.

Environmental monitoring

Monitoring programmes delivered through NABL and CPCB-recognised laboratories.

How we deal with authorities

  • Applications are filed in the occupier's name through the occupier's own portal accounts.
  • We appear before officers only under a written letter of authorisation and only on the record.
  • We do not file monitoring data we have not verified.
  • We will tell you when a unit cannot meet its conditions without changing its process.
Practice area A

Common questions

Does a pharmaceutical formulation unit need Environmental Clearance?

Ordinarily no.

Item 5(f) of the Schedule to the EIA Notification 2006 covers bulk drugs and intermediates and excludes drug formulations.

A formulation-only unit therefore usually needs no prior Environmental Clearance.

It does need Consent to Establish and Consent to Operate from UPPCB, since formulation is generally an Orange-category activity, and in Uttar Pradesh a groundwater NOC from UPGWD.

Bulk drug, API and intermediate manufacture falls under item 5(f) and needs Environmental Clearance through SEIAA or Ministry of Environment, Forest and Climate Change (MoEF&CC) depending on location and capacity.

We confirm the position against the current Schedule and your process before anything is filed.

Do you hold NABET accreditation yourselves?

No. EIA and EMP studies for Environmental Clearance are delivered through NABET-accredited associates, who hold the accreditation. EnvironIQ scopes the study, manages the ToR and appraisal timetable, prepares the proponent for the SPCB-conducted public hearing, and remains your single point of contact throughout.

Does every unit need a Consent to Operate?

No. Units in the White category under the CPCB classification need only to intimate the Board; Green, Orange and Red category units need Consent to Establish and Consent to Operate. We confirm your category before any application is filed.

Which authority grants groundwater NOC in Uttar Pradesh, and can it run in parallel with CTE?

In Uttar Pradesh the NOC is issued by the UP Ground Water Department (UPGWD) under the UP Ground Water (Management and Regulation) Act 2019; elsewhere it runs through the Central Ground Water Authority on the NOCAP portal.

Both need a hydrogeologist-prepared impact assessment and carry telemetry conditions.

For a new unit we normally file the NOC and the Consent to Establish together, since they rest on the same site, water-balance and process data.

What is an Environmental Compliance Status Report?

A dated summary, prepared from the unit's records and a site visit, of the condition-wise status of every consent, authorisation and EC condition the unit holds, with copies, validity dates, the latest monitoring and returns, and any pending notice.

Lenders, buyers and boards ask for it before sanction, purchase or renewal.

It states what the monitoring shows, including gaps.

Our unit has received a show-cause notice from the SPCB. Where do we start?

Start with the reply and the personal hearing.

We build the factual record, draft the technical reply, represent the unit at the hearing under your letter of authorisation and put a time-bound corrective action plan before the Board.

Where a closure direction is in force, our Techno-Legal Support practice (area F) prepares the corrective works and the compliance demonstration on which the Board considers revocation, alongside your counsel.

Start here

Talk to us about clearances and consents

Send the location, what the unit or project is, what has been received or is planned, and any date on it.

We reply within two working days. Your details are used only to answer this enquiry. Privacy policy.